Analog-devices ADSP-2181 Bedienungsanleitung Seite 27

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 26
ADSP-2181/ADSP-2183
REV. 0
–27–
ADSP-2181
Parameter Min Max Unit
IDMA Write, Short Write Cycle
Timing Requirements:
t
IKW
IACK Low before Start of Write
1
0ns
t
IWP
Duration of Write
1, 2
15 ns
t
IDSU
IAD15–0 Data Setup before End of Write
2, 3, 4
5ns
t
IDH
IAD15–0 Data Hold after End of Write
2, 3, 4
2ns
Switching Characteristics:
t
IKHW
Start of Write to IACK High 15 ns
ADSP-2183
28.8 MHz
Parameter Min Max Unit
IDMA Write, Short Write Cycle
Timing Requirements:
t
IKW
IACK Low before Start of Write
1
0ns
t
IWP
Duration of Write
1, 2
15 ns
t
IDSU
IAD15–0 Data Setup before End of Write
2, 3, 4
5ns
t
IDH
IAD15–0 Data Hold after End of Write
2, 3, 4
2ns
Switching Characteristics:
t
IKHW
Start of Write to IACK High 17 ns
NOTES
1
Start of Write = IS Low and IWR Low.
2
End of Write = IS High or IWR High.
3
If Write Pulse ends before IACK Low, use specifications t
IDSU
, t
IDH
.
4
If Write Pulse ends after IACK Low, use specifications t
IKSU
, t
IKH
.
IAD 15–0
DATA
t
IKHW
t
IKW
t
IDSU
IACK
t
IWP
t
IDH
IS
IWR
Figure 29. IDMA Write, Short Write Cycle
Seitenansicht 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 39 40

Kommentare zu diesen Handbüchern

Keine Kommentare